|   print

[  ]
 
Bremmer HJ , Troost LM , Kuipers G , Koning J de , Sein AA

185 p in Dutch   1994

download pdf (7851Kb)  

Toon Nederlands

English Abstract
Based on the results of an inventory of possible dioxin sources other than municipal solid waste (MCW) incinerators, a number of sources not previously measured, are selected for additional measurements. The results of all measurements carried out in the Netherlands, partly supplemented with data from the literature were then elaborated into a total estimate of the dioxin emissions in the Netherlands. In total, the emission to air in 1991 was 484 g I-TEQ. Of that total, the MSW incinerators emit the largest quantity, i.e. 80% of the total. The remainder of the estimated yearly emission is destributed over 16 different process categories. As a result of emission regulating developments it is expected that the dioxin emission in the year 2000 will be descreased to 58 g I-TEQ.

 

RIVM - Bilthoven - the Netherlands - www.rivm.nl

Display English

Rapport in het kort
Abstract niet beschikbaar

 

RIVM - Bilthoven - Nederland - www.rivm.nl

( 1994-02-28 )