Improvement in the design and operation of a sampler for the measurement of suspended particulate matter in the ambient atmosphere (phase II)
[ EG referentie monstername toestel voor vrijzwevend stof ]
 
van der Meulen A, van Elzakker BG, Mark D, Zierock KH

38 p in English   1990

RIVM Rapport 222403001

Toon Nederlands

English Abstract
The performance of the candidate EC reference sampler for thoracic and inhalable particles has been assessed under ambient field conditions. Comparability and precision are at a very acceptable level of a few percent only. The inhalable samples mode does meet a compliance criterium of 10% with the target CEN/ISO convention for inhaled particles. The thoracic option clearly overestimates the pertinent target concentrations (between 20 and 50%).

 