English Abstract A method was developed for the measurement for
polycyclic aromatic hydrocarbons in ambient air by gas chromatography
isotope dilution mass spectrometry. The method was designed to measure the
largest possible volatility range of PAHs including the abundant
naphthalenes. Samples volumes were approx. 500 m3 in size at a sampling
rate of approx. 18 m3/h. The sampler contained three sorption stages for
the simultaneous capturing of particle bound and low and high volatile
gaseous PAHs, respectively. Recoveries of sampling spikes were on average
90 %. The detection limit was approx. 5 pg/m3 for the high boiling range
PAHs. Results obtained showed a quite steady profile for most PAHs in
background air in the Netherlands. Comparison of abundance ratios with data
in the literature indicate that traffic exhausts were the major source for
the PAHs in the area.
Rapport in het kort
Een methode is ontwikkeld voor de meting van poly
aromatische koolwaterstoffen (PAK) in de buitenlucht m.b.v.
gaschromatografie - isotoopverdunning massa spectrometrie. De methode was
ontworpen voor de meting van de grootst mogelijke vluchtigheidstraject
binnen de groep inclusief de meestvoorkomende en vluchtige naftalenen. Het
monstervolume bedroeg circa 500 m3 bij een bemonsteringssnelheid van ca. 18
m3/h. Het monstername apparaat bevatte drie sorptie trappen voor de
simultane bemonstering van resp. de deeltjes gebonden fractie, de weinig
vluchtige en de vluchtige PAK?s. De recoverie van de methode bedroeg
gemiddeld ca. 90 %. De detectiegrens was circa 5 pg/m3 voor de
niet-vluchtig en deeltjes gebonden fractie. Resultaten van toepassing van
de methode in een woongebied (Bilthoven) toonden een vrij stabiel profiel
van voorkomen van de belangrijkste PAK congeneren in achtergrondlucht.
Vergelijking van specifieke verhoudingen van bepaalde PAK congeneren met
literatuur gegevens duidde op een belangrijke bijdrage van verkeer aan PAK?s
in lucht.