English Abstract An analytical procedure has been developed for the
isomer specific determination of polychlorinated biphenyls in background
ambient air. The methodology uses Carbosphere? activated carbon and isotope
dilution HRGC/MS for the isolation and analysis of the toxic fraction of
PCBs in the presence of all other, less or non-toxic congeners. This toxic
fraction includes the non-ortho and mono-ortho PCBs, which recently were
assigned by a WHO/IPCS expert group on toxicity as being the most toxic
congeners. The method provides quantification limits ranging from 0.01 to
0.08 pg/m3. Mean atmospheric levels for the sum of these congeners varied
between 3.0 and 5.0 pg/m3 with some events with higher concentrations.
PCB 126 typically present at 0.03 pg/m3 was found to contribute for 77 % of
the total toxic equivalent (TEQ) values in air samples.
Rapport in het kort
Een analytische methode is ontwikkeld voor de
isomeer-specifieke bepaling van meervoudig gechloreerde biphenylen (PCB?s)
in achtergrond buitenlucht. De gebruikte methodologie bestaat uit de
monstername, isolatie en zuivering van PCB?s in extracten en analyse m.b.v.
isotoop verdunning HRGC/MS. De analyse betreft de non en mono-ortho
gesubstitueerde fractie, welke als de meest toxische congeneren worden
beschouwd. De kwantificeringslimiet van de methode voor de verschillende
congeneren lag tussen 0.01 en 0.08 pg/m3. De gemeten niveau?s als som van
de congeneren in de buitenlucht varieerde tussen 3 en 5 pg/m3, met sommige
omstandigheden met hogere concentraties. PCB 126, met een voorkomen van
circa 30 pg/m was de belangrijkste congeneer op toxiciteitsbasis en droeg
gemiddeld 77 % bij aan de berekende toxiciteits equivalentie hoeveelheid
(TEQ) in luchtmonsters.