Matthijsen AJCM ,
Jaarsveld JA van ,
Jong APJM de ,
Ros JPM ,
Schutter MAA ,
Vos JJ
17 p
in Dutch
1990
Toon Nederlands
English Abstract The results of the emission measurements at the
municipal solid waste incinerator (MWI) in Alkmaar show that during this
period the Directive 'Incineration 1989' has been exceeded. The measured
emission of chlorinated dioxins and furans from this installation has to be
considered as an average value for this type of installation. The yearly
emission of these compounds is estimated to be 21 g TEQ/year. According to
dispersion model calculations this emission contributes considerably to the
yearly mean deposition in the direct surroundings, viz. on average 7 (6-10)
ng TEQ/m2. year) on an area of 20 x 20 km2 and a maximum of 33 (29-45) ng
TEQ/m2. year) at 2,500 m North-east of the installation. At this moment
there is still a lack of knowledge about further behaviour, deposition,
uptake and fate in the cow, which makes it impossible to calculate the
concentration in the milk of cows in the vicinity of a MWI. However a
calculation model is in a developing stage and probably an empirical
relation will also offer some possibilities.