- Publicatiedatum
- 11-02-2026
Gamma radiation dose measured at the site boundary of COVRA N.V. with the MONET network in 2024
Gamma radiation dose measured at the site boundary of COVRA N.V. with the MONET network in 2024
Samenvatting
Het RIVM meet elk jaar het niveau van gammastraling aan de terreingrens van de Centrale Organisatie Voor Radioactief Afval (COVRA N.V.) in Borsele. Dit niveau was in 2024 lager dan het maximum van 40 microsievert per jaar waarvoor de vergunning is verleend. De hoogste gemeten dosis blijkt 3,3 microsievert. Hiermee voldoet COVRA (Centrale Organisatie Voor Radioactief Afval) aan de eis uit de vergunning.
COVRA moet ervoor zorgen dat mensen buiten de terreingrens aan een zo laag als redelijkerwijs mogelijke dosis worden blootgesteld, onder het maximum van 40 microsievert. Dat is in de kernenergiewetvergunning vastgelegd.
In dit rapport staan de metingen, gemiddeld over tien minuten, van de twaalf MONET-monitoren aan de terreingrens van COVRA in 2024. Om de effectieve dosis te bepalen wordt het gammastralingsniveau op twaalf locaties langs de terreingrens gemeten. Het RIVM doet deze metingen met het zogenoemde MONET-meetnet. De metingen op een locatie zijn representatief voor de hoeveelheid gammastraling die van nature voorkomt (natuurlijke achtergrondwaarde). Van de metingen op de andere elf locaties wordt deze hoeveelheid gammastraling afgetrokken.
Ten slotte wordt de meetwaarde gecorrigeerd met de zogeheten Actuele Blootstellings Correctiefactor (ABC-factor). Een ABC-factor hangt samen met de bestemming van het gebied waar mensen kunnen blootstaan aan de stralingsdosis.
Het RIVM rapporteert en toetst de gammastraling aan de terreingrens elk jaar in opdracht van de Autoriteit Nucleaire Veiligheid en Stralingsbescherming (ANVS).
Abstract
Each year, the National Institute for Public Health and the Environment (RIVM) measures the gamma radiation dose at the site boundary of the Central Organisation For Radioactive Waste (Centrale Organisatie Voor Radioactief Afval, COVRA) in Borssele. In 2024, this dose was below the maximum of 40 microsievert per year (μSv/y) permitted at the site boundary. The highest measured dose was 3.3 μSv. This means COVRA meets the relevant criterion in its operating licence.
COVRA has a duty to ensure that the exposure to radiation of people outside the site boundary is as low as reasonably possible, below the maximum of 40 microsievert per year (μSv/a). This is pursuant to its operating licence under the Nuclear Energy Act.
This report provides the measurements, averaged over intervals of ten minutes, of the radiation dose recorded by the 12 MONET monitors at the boundary of the COVRA site in 2024. To determine the effective dose, the gamma radiation dose is measured in 12 locations along the site boundary. RIVM conducts these measurements through the MONET monitoring network. The measurements at one location are representative of the dose of gamma radiation that occurs naturally (natural background value). This quantity is subtracted from the measurements at the other eleven locations.
Lastly, the measurement value is corrected using the Actuele Blootstelling Correctiefactor (or ABC factor, meaning actual exposure correction factor). An ABC factor takes into account the specific use of the area where people may be exposed to the radiation dose.
RIVM is tasked by the Authority for Nuclear Safety and Radiation Protection (Autoriteit Nucleaire Veiligheid en Stralingsbescherming, ANVS) to monitor the gamma radiation at the site boundary and report on this annually.
Uitgever
- Instituut
- Rijksinstituut voor Volksgezondheid en Milieu RIVM
Resterend
- Grootte
- 920 kb